| Closed tools used as the only means of protection [see ISO 16092-1:2017 a)] |
Movement (e.g. closing stroke) of the slide, die cushions, workpiece ejectors |
Cycle initiation/ stop |
PL a |
Cat B |
Anyg |
Any |
Pneumatic system (e.g. air valves) |
| Closed tools used in a press with other operating modes with different main safety systems [see ISO 16092-1:2017 a)] |
| Fixed enclosing guard used as the only means of protection [see ISO 16092-1:2017 b)] |
Movement (e.g. closing stroke) of the slide, die cushions, workpiece ejectors and transfer systems |
Cycle initiation/ stop |
PL a |
Cat B |
Anyg |
Any |
Pneumatic system (e.g. air valves) |
Interlocking guard with or without guard locking (with or without early opening feature) or control guard (with or without early opening feature)[see ISO 16092-1:2017 c), d) and e)] |
Movements (e.g. closing stroke) of the slide and die cushions |
Cycle initiation by other control device than the guard |
PL a |
Cat B |
Any but not actuated by the guard itselfg |
Any |
Logic control shall act on the appropriate part of the pneumatic or electrical control system |
Interlocking guard with or without guard locking (with or without early opening feature) or control guard (with or without early opening feature)[see ISO 16092-1:2017 c), d) and e)] |
Movements (e.g. closing stroke) of the slide and die cushions |
Cycle initiation by control guard |
PL a |
Cat B |
Interlocking device of the guard |
Any |
Logic control shall act on the appropriate part of the pneumatic or electrical control system |
| Stop by interlocking device of guard without guard locking [see ISO 16092-1:2017 b)] |
PL eb,c |
Cat 4 |
Interlocking device (2 sensors or equivalent solution)e,f |
Safety-related logic |
Pneumatic system (e.g. air valves) |
| Stop by interlocking device of guard with guard locking [see ISO 16092-1:2017 a)] |
Interlocking device with guard locking (2 sensors or equivalent solution)e,f |
Interlocking guard with or without guard locking (with or without early opening feature) or control guard (with or without early opening feature)[see ISO 16092-1:2017 c), d) and e)] |
Movements (e.g. closing stroke) of the slide and die cushions |
Conditional unlocking of guard |
PL d |
Cat 3 for input and logic, Cat 2j for output |
Sensor or other suitable detection device to confirm that standstill of slide and die cushion is achieved |
Safety-related logic |
Pre-actuator of the guard locking |
| Movements (e.g. closing stroke) of the slide and die cushions |
Muting in case of early opening guard and control guard without guard locking [see ISO 16092-1:2017, 5.4.2] |
Same as of the safety function on which muting is actingq |
— |
Position signal or suitable alternative |
— |
— |
Interlocking guard with or without guard locking (with or without early opening feature) or control guard (with or without early opening feature)[see ISO 16092-1:2017 c), d) and e)] |
Movements of work-piece ejectors and transfer systems |
Stop by interlocking device of guard without guard locking [see ISO 16092-1:2017 b)] |
PL db,d |
Cat 3 |
Interlocking device (2 sensors or equivalent solution)e,f |
Safety-related logic |
Electrical, hydraulic or pneumatic system |
| Stop by interlocking device of guard with guard locking [see ISO 16092-1:2017 a)] |
PL db,d |
Cat 3 |
Interlocking device with guard locking (2 sensors or equivalent solution)e,f |
Safety-related logic |
Electrical, hydraulic or pneumatic system |
Interlocking guard with or without guard locking (with or without early opening feature) or control guard (with or without early opening feature)[see ISO 16092-1:2017 c), d) and e)] |
Movements of work-piece ejectors and transfer systems |
Conditional unlocking of guard |
PL c |
Cat 3 for input and logic, Cat 2j for output |
Sensor or other suitable detection device to confirm that standstill of work-piece ejectors and transfer systems is achieved |
Safety-related logic |
Pre-actuator of the guard locking |
| Muting in case of early opening guard and control guard without guard locking [see ISO 16092-1:2017] |
Same as of the safety function on which muting is actingq |
— |
Position signal or suitable alternative |
— |
— |
Interlocking guard with or without guard locking (with or without early opening feature) or control guard (with or without early opening feature)[see ISO 16092-1:2017 c), d) and e)] |
Movements of the slide, die cushions, workpiece ejectors and transfer systems |
Prevention of restart by an additional safeguarding of a control guard by AOPD [see ISO 16092-1:2017] |
PL en |
Cat 4 |
AOPD |
Safety-related logic |
Logic control shall act on the appropriate part of the electrical control system |
Interlocking guard with or without guard locking (with or without early opening feature) or control guard (with or without early opening feature)[see ISO 16092-1:2017 c), d) and e)] |
Movements of the slide, die cushions, workpiece ejectors and transfer systems |
Prevention of restart by an additional safeguarding of a control guard by interlocking guard [see ISO 16092-1:2017] |
PL co,p |
Cat 1 for input, Cat 3 for logic and output |
Interlocking device |
Safety-related logic |
Logic control shall act on the appropriate part of the electrical control system |
| Interlocking guard with or without guard locking [see ISO 16092-1:2017] |
Drive and transmission[see ISO 16092-1:2017] |
Stop by interlocking device of guard without guard locking |
PL c |
Cat 1 |
Interlocking device |
Safety-related logic |
Electric, hydraulic or pneumatic system |
| Stop by interlocking device of guard with guard locking |
| Interlocking guard with or without guard locking [see ISO 16092-1:2017] |
Drive and transmission[see ISO 16092-1:2017] |
Conditional unlocking of guard |
PL c |
Cat 1 |
Sensor or other suitable detection device to confirm that standstill of drive and transmission is achieved |
Safety-related logic |
Pre-actuator of the guard locking |
| Interlocking guard opened for tool setting only [see ISO 16092-1:2017 c) and 5.5.6] |
Movements of the slide, die cushions, work-piece ejectors and transfer systems |
Stop by interlocking device of guard |
PL c |
Cat 1 for input, Cat 3 for logic and output |
Interlocking device |
Safety-related logic |
Same output than those used for safeguarding measures used in production mode |
| ESPE using AOPD [see ISO 16092-1:2017 f) and 5.3.2.11] |
Movements (e.g. closing stroke) of the slide and die cushions |
Cycle initiation by other control device than the AOPD |
PL a |
Cat B |
Any but not actuated by the AOPD itselfg |
Any |
Logic control shall act on the appropriate part of the electrical control system |
| ESPE using AOPD [see ISO 16092-1:2017 f) and 5.3.2.11] |
Movements (e.g. closing stroke) of the slide and die cushions |
Cycle initiation by AOPD |
PL a |
Cat B |
AOPD |
Any |
Logic control shall act on the appropriate part of the electrical control system |
| ESPE using AOPD [see ISO 16092-1:2017 f) and 5.3.2.11] |
Movements (e.g. closing stroke) of the slide and die cushions |
Stop by AOPD |
PL ec |
Cat 4 |
AOPD |
Safety-related logic |
Pneumatic system (e.g. air valves) |
| ESPE using AOPD [see ISO 16092-1:2017 f) and 5.3.2.11] |
Movements (e.g. closing stroke) of the slide and die cushions |
Muting [see ISO 16092-1:2017] |
Same as of the safety function on which muting is actingq |
— |
Position signal or suitable alternative |
— |
— |
| Movements of work-piece ejectors and transfer systems |
Stop by AOPD |
PL dd |
Cat 3 |
AOPD |
Safety-related logic |
Electrical, hydraulic or pneumatic system |
| Muting [see ISO 16092-1:2017] Not allowed for transfer system |
Same as of the safety function on which muting is actingq |
— |
Position signal or suitable alternative |
— |
— |
| Movements of the slide, die cushions, workpiece ejectors and transfer systems |
Prevention of restart by an additional safeguarding by AOPD [see ISO 16092-1:2017 c)] |
PL d |
Cat 3 |
AOPD |
Safety-related logic |
Logic control shall act on the appropriate part of the electrical control system |
| ESPE using AOPD [see ISO 16092-1:2017 f) and 5.3.2.11] |
Movements of the slide, die cushions, workpiece ejectors and transfer systems |
Prevention of restart by an additional safeguarding by interlocking guard [see ISO 16092-1:2017 c)] |
PL co,p |
Cat 1 for input, Cat 3 for logic and output |
Interlocking device |
Safety-related logic |
Logic control shall act on the appropriate part of the electrical control system |
| Two-hand control device [see ISO 16092-1:2017 g) and 5.3.2.12] |
Movements (e.g. closing stroke) of the slide and die cushions |
Stop and cycle initiation by two-hand control device |
PL eb,c |
Cat 4 |
Push buttons of two-hand control deviceg,h |
Safety-related logic |
Pneumatic system (e.g. air valves) |
| Two-hand control device [see ISO 16092-1:2017 g) and 5.3.2.12] |
Movements (e.g. closing stroke) of the slide and die cushions |
Stop and cycle initiation for pneumatic presses with a stroke length equal or less than 30 mm and a maximum press force of 1 000 N or less (see 5.4.1.8) |
PL db,d |
Cat 3 |
Push buttons of two-hand control deviceg,h |
Safety-related logic |
Pneumatic system (e.g. air valves) |
| Muting (see ISO 16092-1:2017) |
Same as of the safety function on which muting is actingq |
— |
Position signal or suitable alternative |
— |
— |
| Movements of work-piece ejectors and transfer systems |
Stop and cycle initiation by two-hand control device |
PL db,d |
Cat 3 |
Push buttons of two-hand control deviceg,h |
Safety-related logic |
Electrical, hydraulic or pneumatic system |
| Two-hand control device [see ISO 16092-1:2017 g) and 5.3.2.12] |
Movements of work-piece ejectors and transfer systems |
Muting (see ISO 16092-1:2017) Not allowed for transfer system |
Same as of the safety function on which muting is actingq |
— |
Position signal or suitable alternative |
— |
— |
| Movements of the slide, die cushions, workpiece ejectors and transfer systems |
Additional means to restrict access (see ISO 16092-1:2017) Stop by interlocking device of guard |
PL db,d |
Cat 3 |
Interlocking device (2 sensors or equivalent solution) |
Safety-related logic |
Electrical, hydraulic or pneumatic system |
| Additional means to restrict access (see ISO 16092-1:2017) Stop by ESPE using AOPD or AOPDDR |
PL dd |
AOPD or AOPDDR |
| Safety systems which need reset |
Movements of the slide, die cushions, work-piece ejectors and transfer systems |
Manual reset (see ISO 16092-1:2017) |
Same as of the safety function on which it is actingm |
Any Cat for inputl, Same category as of the selected safety functions for logic and output |
Push button |
Safety-related logicl |
Logic control shall act on the appropriate part of the electrical control system |
| Safety systems which need selection means |
Means of selection (see ISO 16092-1:2017) |
Same as the highest PLr among the selected functions |
Selection means, e.g. selector switch, electronic key system |
Safety-related logic to check plausibility of inputsi |
| Mechanical restraint device |
Movements of the slide |
Interlocking to the press control system (see 5.3.7) |
PL c |
Cat 1 |
Interlocking device |
Safety-related logic |
Pneumatic system (e.g. air valves) |
| Emergency stop device |
Movement (e.g. closing stroke) of the slide, die cushions, workpiece ejectors and transfer systems |
Emergency stop function (see ISO 16092-1:2017) |
PL c |
Cat 1 |
Emergency stop push buttonh |
Safety-related logic |
Electrical, hydraulic or pneumatic system (e.g. air valves) |
| a In the table, “Requirement for category of Input, Logic and Output” means the following relationships between the requirements of categories for Input, Logic or Output part: |
| — Cat. 4, 3 or 2 can apply instead of Cat. 1; — Cat. 4 or 3 can apply instead of Cat. 2; — Cat. 4 can apply instead of Cat. 3. |
| b Fault exclusion (e.g. mechanical break) of a sensor is not acceptable. c Functional safety described in ISO 16092-1:2017, 5.4.1.4 a) to e), shall apply. d Functional safety described in ISO 16092-1:2017, 5.4.1.4 a) to c), and if reasonably practicable ISO 16092-1:2017, 5.4.1.4 d) to e), shall apply. e Plausibility check required or equivalent solution, e.g. 1 system fulfilling the required PL by itself. f See ISO 14119 for the design of interlocking device of guard with guard locking. g In case of mobile control device (e.g. foot pedal) provision shall be made to ensure that unintended start-up due to a short circuit in the cable connecting the control device to the control system is prevented. h In case of mobile control device, provision shall be made to ensure that the stop function remains operational in case of a short circuit in the connecting cable to the control system. i Plausibility check of inputs shall be provided and shall insure that one selected position and the relevant safety measures are still operative without any mal-function or dangerous movements are stopped. j This part can be considered of category 2 if, either demand rate ≤1/100 test rate; or testing occurs immediately upon demand of the safety function and a detected fault leads immediately to a stop of the machine (stop by the output of the testing part of the category 2 system — see NOTE of ISO 13849-1:2015). Restart of the machine shall only be possible after repair. k If required. It depends on the design and structure of the machine. l No specific category is required for input, because logic part will only act after actuation or de-actuation of the input, and any blocking of the input will not lead to any new reset (see ISO 16092-1:2017). m Manual rest function, which is related to a protective device placed where there is no possibility of access of the whole body of a person into the danger zone, may not be subjected to the requirements of PL on this table as a safety function. Only ISO 16092-1:2017 is applied. n F2 is based on the assumption that the additional safeguarding by AOPD is provided to cover the space between the primary protective measure (control guard or ESPE) and the danger zone where a person enters frequently, e.g. at every cycle. o The additional safeguarding by interlocking guard shall not be opened frequently during production (e.g. it is opened only for tool setting, trial or maintenance). Where this is not practicable, other means shall be used. p In the case of additional safeguarding by interlocking guard, P1 is assigned because the guard is in place as a physical obstacle. Even if the interlocking device fails, it is possible that an operator recognizes the guard is removed or opened before initiating a stroke (if additional safeguarding is by AOPD: in case of a failure, an operator can stand undetected between the control guard/primary AOPD and the danger zone). q No specific PL is required for this sub function which shall be considered as an internal part of the safety functions on which it is acting. This internal part shall be taken into account in the evaluation of the PL of the relevant safety functions. |